4-43
4
Daily Maintenance
Checking method of UV illumination intensity
UV lamp is a consumable. The more the irradiation time increases, the more the amount of light decreases
and the ink will become hard to harden. When the cumulative irradiation time exceeds a certain value, a
message prompting you for checking the illumination intensity is displayed on the operation panel.
Check the UV lamp illumination intensity following this operation manual and use it as a reference when
replacing the UV lamp.
Notes when checking the illumination intensity
Tools required checking the illumination intensity
Be sure to wear the attached goggle and the gloves.
Wear long sleeves in order to protect your skin from the UV lamp.
Illumination meter
bracket(M510110)
Screw x 2 (B5x10) and
Phillips screwdriver
Illumination meter