4-33
Setting periodical operations in stand-by mode [ROUTINE SETUP]
Refresh Interval while in stand-by mode [REFERSH]
Set the interval at which refreshing operation is to be performed periodically.
STEPS:
1 Make sure that the printer is in LOCAL mode, and then select [MAINTENANCE] using
the [FUNCTION] key and press the [ENTER] key.
If it is in REMOTE mode, press the [REMOTE] key.
2 Select [ROUTINE SETUP] by pressing the [] key six times and press the [ENTER]
key.
When using water-based ink, press again the [ENTER] key and proceed to Step 4.
3 Select [REFRESH] by pressing the [] key once and press the [ENTER] key.
4 Input the interval at which refreshing operation is to be performed periodically, using
the [] or [] key.
Input range: OFF, 1 to 168
Register the setting by pressing the [ENTER] key.
5 Press the [END] key several times.
The printer returns to LOCAL mode.
L. > [JV5-01]
width : ∗∗∗∗ mm
FUNCTION
MAINTENANCE <ENT>
MAINTENANCE
ST.MAINTENANCE <ent>
MAINTENANCE
ROUTINE SETUP <ent>
6
times
Once
Wiping in the
drawing is set up.
ROUTINE SETUP
ROUTINE WIPING <ent>
RefreshIntervalInThe
stand by is set up.
ROUTINE SETUP
REFRESH <ent>
ROUTINE SETUP
REFRESHinterval = 1h
L. > [JV5-01]
width : ∗∗∗∗ mm
Vue de la page 174