Vue de la page 53
3-2
Changing origin
The default origin position can be changed.
There are following 2 changing methods.
Changing origin with JOG keys
1
Press the keys
in the local mode.
The origin setting mode starts
A red light pointer mark [ ] is projected on the table or the media.
2
Move the light pointer mark by pressing the
keys.
Move the light pointer mark to the position to set a new origin.
3
Press the key when the drawing origin is
determined.
The origin is changed.
The height of the table is also fixed at the same time. Adjust the height of the table by pressing the
TABLE keys in advance.
The setting value for the origin set with the JOG keys is cleared by cutting the power.
The setting of the table height holds even if turning off the power.
Changing with the JOG keys Changing with the “ORIGIN”
in the FUNCTION menu
OR I G I N SET UP
0.0
---
OR I G I N SET UP
420 . 0 300 . 0
Origin position
(back and forth)
Origin position
(right and left)
** ORIGIN **
ENTER
Vue de la page 53