Setting the Head Height
3
Useful Function
Setting the media thickness
If the media thickness is changed, Table Height is also changed.
1
Press the key in the local mode.
2
Select the [HEAD HEIGHT] by pressing the or
key, and press the key.
3
Select the [MEDIA THICKNESS] by pressing the or
keys, and press the key.
4
Set the media thickness by pressing the or
keys, and press the key.
Set value 100.0 to 150.0mm (When there is no table spacer)
50.0 to 100.0mm (When the table spacer is the one for 50mm)
0.0 to 50.0mm (When the table spacer is the one for 100mm)
5
Press the key several times to end the setting.
When you set the media thickness of 100mm, it is necessary to attach the vacuum table and the table
spacer so that the media thickness may become 100mm.
Adjust [MEDIA THICNESS] or [TABLE HEIGHT] based on the head gap value so that [HEAD GAP] +
[MEDIA THICNESS] + [TABLE HEIGHT] = 151.5mm.
If adjustment cannot be performed, an operation error is displayed.
<LOCAL>
FUNCTION
FUNCT I ON
WOR K S E T < E N T >
ENTER
HEAD HE I GHT
MEDIA THICKNESS<ent>
ENTER
HEAD HE I GHT S : 1 0 0
TH I CKNESS : 10 0mm
ENTER
END