MIMAKI JV5-160S Spécifications Page 100

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 262
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 99
CHAPTER 3 Print Output Setting the reference value for dot misalignment correction
3-28
5 Press the [] or [] key to correct the dot position of pattern 1.
Select the correct dot position on [PATTERN 1] using the JOG key [] or [].
Select the dot position where the dots of outward trip and those of homeward trip form a straight line on the test
pattern.
6 Press the [ENTER] key.
7 Subsequently repeat Steps 5 and 6 seven times to make PG DROP ADJUSTMENT on
Pattern 2 to Pattern 8.
Select the correct dot position on each of the patterns.
Enter the adjusted values on Patterns 1 to 8 and then terminate PG DROP ADJUSTMENT.
8 Press the [END] key several times.
The printer returns to LOCAL mode.
Dots may be slightly out of alignment even after [PG DROP ADJUST.] is made.
In such a case, perform [DROP.POScorrect] of [MAINTENANCE].
The procedure for [DROP.POScorrect] is the same as that for [PG DROP
ADJUST.], but the test patterns to be used are [Pattern 1] to [Pattern 4].
(See 3-36)
Input COMP value.
-40.0 - +40.0
PG DROP ADJUST.
PATTERN1 = 0.0
Input range:
Patterns 1 to 8
-40.0 to 40.0
Output direction
The dots at the fourth position counted
from the zero position in the positive
direction form a straight line.
In this case, the adjusted value is 4.0.
Input COMP value.
-40.0 - +40.0
PG DROP ADJUST.
PATTERN2 = 0.0
Input range:
Patterns 1 to 8
-40.0 to 40.0
PRE PRT AFT
35°C 40°C 50°C
L. > [JV5-01]
width : ∗∗∗∗ mm
Vue de la page 99