MIMAKI JV5-160S Spécifications Page 195

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 262
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 194
6-5
CHAPTER 6 Operation for Functions Invoking SET UP functions
Outline of the setup functions
MEDIA COMP. (See 3-34)
When the media type or any heater temperature is changed, be sure to correct the feed rate to meet the
media thickness. (Correction value: -255 ~ 255)
MediaFeed SETUP
Set particulars related to media feed.
The table below shows the setting items.
FEED METHOD
Select a method for detecting the feed rate of media.
Available setting values: [DIRECT, NORMAL]
The setting values for each user type are stored separately from those for other user types.
SPEED SWITCHING
Set the feed speed level.
Available setting values: [200% ~ 10%]
The setting values for each user type are stored separately from those for other user types.
MOVEMENT TEST
Perform testing to see whether or not the media is compatible with the direct detection method using the
media encoder.
When the feed error is not within 0.4 %, the display shows a recommended feed method.
HEATER (See 6-29)
Make settings of the pre-heater, print heater and after-heater built in the platen.
FEED METHOD Switches between methods for detecting the feed rate of media.
SPEED SWITCHING Sets the media feed rate.
MOVEMENT TEST
Performs testing whether or not the media is compatible with the direct detection method
using the media encoder.
DIRECT Feed rate control with the motor encoder + Location detection with the media encoder (Default)
NORMAL Feed rate control with the motor encoder
Vue de la page 194