6-29
CHAPTER 6 Operation for Functions Applied settings of functions
Applied settings of functions
Initial settings can be changed, as required.
Settings of heaters
Setting items for heaters
The items that can be set for the three heaters are as described below.
SET TEMP.
Set temperature for each of the three heaters.
SET TIME
Set the standby time and the time for turning OFF.
PRE HEAT
Set the temperature of the pre-heater.
(OFF, 20 ~ 60° C / 68 ~ 140° F)
PRINT HEAT
Set the temperature of the print-heater.
(OFF, 20 ~ 60° C / 68 ~ 140° F)
AFTER HEAT
Set the temperature of the after-heater.
(OFF, 20 ~ 70° C / 68 ~ 158° F)
STANDBY
Set the period of time from when printing is completed to when the heater temperature begins to
drop to the preheat temperature.
The preheat temperature is preset and cannot be changed.
If the printer receives data at the preheat temperature, the heaters automatically raise their temper-
atures up to the preset levels and then the printer starts printing.
When [NONE] is selected, the temperatures do not drop to the preheat level.
(NONE, 0- 90 min / In steps of 10 minutes)
OFF TIME
The heaters are turned off in the following case:
If a preset time has passed without printing while the printer is in standby mode.
With STANDBY-[NONE] selected, there may be a case where a preset time passes without
printing after some printing and thus the heaters are turned off. If the printer receives data with
the heaters turned off, the heaters are automatically turned on to raise their temperatures up to
the preset levels and then the printer starts printing.
With [NONE] selected, the heaters are not turned off.
(NONE, 0 - 90 min / In steps of 10 minutes)
Commentaires sur ces manuels