Vue de la page 70
2-33
CHAPTER 2 Basic Use of Printer About Function Menus
NCU functions
Function name Sub function Setting value Function
NOZZLE CHECK (p. 6-26) ON, OFF Set whether or not to perform nozzle
missing detection.
NG ACTION (*1)
[DURING THE
DRAW] (p. 6-26)
CONTINUE Set the operation of the printer to be
performed during printing in case a
certain level of nozzle missing is
detected and thus NG judgment is
made. (*2)
CLEAN-
ING&CONT
CLEANING
TYPE
NORMAL, SOFT, HARD
CLEAN-
ING&STOP
CLEANING
TYPE
NORMAL, SOFT, HARD
RETRY COUNT 0 to 3
STOP
NG ACTION (*1)
[AFTERtheDRA-
Wend] (p. 6-27)
CONTINUE Set the operation of the printer to be
performed after completion of print-
ing of one file in case a certain level
of nozzle missing is detected and
thus NG judgment is made. (*2)
CLEAN-
ING&CONT
CLEANING
TYPE
NORMAL, SOFT, HARD
CLEAN-
ING&STOP
CLEANING
TYPE
NORMAL, SOFT, HARD
RETRY COUNT 0 to 3
STOP
NG JUDGEMENT
(*1) (p. 6-27)
CLOGG NZL/color 1 to 180 Set the number of missing nozzles
per row for judging the nozzle check
NG . (*2)
CLOGG NZL/ALL 1 to 180 Set the total number of missing noz-
zles for judging the nozzle check
NG . (*2)
COND.INDICATION (p. 6-27) Displays the status of the NCU.
This function displays every error
that has occurred in the NCU and
every error that has occurred
between NCU Main Unit.
Using the [] or [] key, the errors
can be displayed one by one in the
order of occurrence.
NG (*1): Bad nozzle condition.
NG (*2): One or more bad nozzles have been located on print head.