CHAPTER 6 Operation for Functions Applied settings of functions
6-30
Detailed settings of heaters
Make settings of the pre-heater, print-heater and after-heater built in the platen.
The temperatures of heaters can be adjusted even during printing so that optimum temperatures can be
obtained.
However, it takes a heater a few minutes to more than ten minutes to reach the set temperature depending
on the ambient temperature.
The temperature settings made here will be kept until the power is turned off or they are changed under any
of the following conditions:
Types are changed in FUNCTION mode.
Heater temperatures are changed in FUNCTION mode.
The heater temperatures are set on the computer.
Setting value of temperature
Rough guide for temperature setting
*1 Adjust each heater temperature to a value best suited to the media conditions.
Use this printer at 20-35° to ensure reliable printing. The heater temperatures
may not rise to the set values depending on the ambient temperature.
The heater temperatures can be controlled on your application software if it
has a function to do so.
For setting on the application software, refer to the instruction manual for your
application software.
° C OFF, 20~60 (70) ° C (In steps of 1 ° C)
° F
OFF, 68~140 (158) ° F (In steps of ° F)
* There may be some values that cannot be set in steps of 1 ° F.
Heater ES3 ink (media) HS ink
PVC Tarpaulin FF All types of media
Pre-heater 40 40 40 40
Print-heater 40 40 40 40
After-heater 50 50 50 50