4 Daily Maintenance
4-4
Replace the filter of the slider fan.
Replace the filter periodically to maintain the performance of the slider fan.
(SPC-0630/head fan filter set [sold separately])
It is recommended to replace the filter per 1000m
2
drawing.
STEPS:
1 Make sure that the printer is in LOCAL mode.
If it is in REMOTE mode, press the [REMOTE] key.
2 Press the [ST.MAINT] key and press the [ENTER] key.
When [CARRIAGE OUT] is displayed, press the [ENTER] key. Then the carriage moves to above the platen.
3 Open the front cover.
4 Remove the knurled screws fixing the filter (two
positions for one side).
5 Replace the filter located between the filter plates.
The slider fan is located on both sides of the carriage. When replacing, replace both fil-
ters.
L. *> [JV5-01]
width : ****mm
ST.MAINTENANCE
CARRIAGE OUT <ENT>
Remove the
knurled screws.
Replace
Be careful about
the position of the
notch